Salt Composition Recommendations

Component Chemical Symbol Composition Component Chemical Symbol Composition
Sodium Chloride NaCl 99.7 % Insoluble Sulfates SO4 ≤ 1500mg/kg
Potassium K ≤ 70mg/kg Magnesium Mg ≤ 1mg/kg
Calcium Ca ≤ 20mg/kg Copper Cu ≤ 0.1mg/kg
Iron (free) Fe ≤ 2mg/kg      

 

Technical characteristics and requirements of the generator

Generator type   T25N0040 T25N0080 T25N0150 T25N0250
Neuthox production L/H 40 80 150 250
Free chlorine Minimum mg/liter 500 500 500 500
Water supply bar 3 - 7 3 - 7 3 - 7 3 - 7
Approximate salt comsumption Kg/day 1 - 2 3 - 4 7 - 8 12 - 15
Brinetank Liters 300 300 300 300
Water connection * BSP male ½" ½" ½" ½"
Drain hose mm 10 10 10 10
Drain hose length Meters 5 5 5 5
Backpressure Bar <0,2 <0,2 <0,2 <0,2
           
Power requirements ( 5 core ) ** V 3 x 400 3 x 400 3 x 400 3 x 400
3 phase A 16 16 16 16
      W 700 1060 1420 2740
External dosing pump max consumption. W 100 100 100 100
           
Room ventilation m³/h > 15 > 24 > 33 > 66
Ambient temperature min/max °C +5 to +30 +5 to +30 +5 to +30 +5 to +30
           
Dimension Generator
Weight kg 160 175 180 185
Width mm 850 850 850 850
Height mm 1490 1490 1490 1490
Depth mm 460 460 460 460

 

* Water shutoff valve located within 3 m

 

** Power connection: Switched IP44 compliant within 3 m. The generator has a 5 m ( 5 core ) 3 phase, ground ( earth ) and common (neutral) power lead.